Element Position Calibration for Matrix Array Transducers with Multiple Disjoint Piezoelectric Panels

Abstract

Two-dimensional ultrasound transducers enable the acquisition of fully volumetric data that have been demonstrated to provide greater diagnostic information in the clinical setting and are a critical tool for emerging ultrasound methods, such as super-resolution and functional imaging. This technology, however, is not without its limitations. Due to increased fabrication complexity, some matrix probes with disjoint piezoelectric panels may require initial calibration. In this manuscript, two methods for calibrating the element positions of the Vermon 1024-channel 8 MHz matrix transducer are detailed. This calibration is a necessary step for acquiring high resolution B-mode images while minimizing transducer-based image degradation. This calibration is also necessary for eliminating vessel-doubling artifacts in super-resolution images and increasing the overall signal-to-noise ratio (SNR) of the image. Here, we show that the shape of the point spread function (PSF) can be significantly improved and PSF-doubling artifacts can be reduced by up to 10 dB via this simple calibration procedure.

Get full access to this article

View all access and purchase options for this article.

References

1. Christensen-Jeffries K, Couture O, Dayton PA, Eldar YC, Hynynen K, Kiessling F, et al. Super-resolution ultrasound imaging. Ultrasound Med Biol. 2020;46(4):865-91.
2. Chavignon A, Heiles B, Hingot V, Orset C, Vivien D, Couture O. 3D transcranial ultrasound localization microscopy in the rat brain with a multiplexed matrix probe. IEEE Trans Biomed Eng. 2022;69(7):2132-42.
3. Demeulenaere O, Bertolo A, Pezet S, Ialy-Radio N, Osmanski B, Papadacci C, et al. In vivo whole brain microvascular imaging in mice using transcranial 3D ultrasound localization microscopy. EBioMedicine. 2022;79:103995.
4. McCall JR, Santibanez F, Belgharbi H, Pinton GF, Dayton PA. Non-invasive transcranial volumetric ultrasound localization microscopy of the rat brain with continuous, high volume-rate acquisition. Theranostics. 2023;13:1235-46.
5. McCall JR, DeRuiter R, Ross M, Santibanez F, Hingtgen SD, Pinton GF, Dayton PA. Longitudinal 3-D visualization of microvascular disruption and perfusion changes in mice during the evolution of glioblastoma using super-resolution ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control. 2023;70(11):1401-16.
6. Lazebnik R, Desser T. Clinical 3D ultrasound imaging: beyond obstetrical applications. Diagn Imaging. 2007;1:1-6.
7. Artul S, Nseir W, Armaly Z, Soudack M. Superb microvascular imaging: added value and novel applications. J Clin Imaging Sci. 2017;7:45.
8. Gummadi S, Eisenbrey J, Li J, Li Z, Forsberg F, Lyshchik A, et al. Advances in modern clinical ultrasound. Adv Ultrasound Diagn Ther. 2018;2(2):51-63.
9. Cao K, Mills DM, Thiele RG, Patwardhan KA. Toward quantitative assessment of rheumatoid arthritis using volumetric ultrasound. IEEE Trans Biomed Eng. 2016;63(2):449-58.
10. Harput S, Christensen-Jeffries K, Ramalli A, Brown J, Zhu J, Zhang G, et al. 3-D super-resolution ultrasound imaging with a 2-D sparse array. IEEE Trans Ultrason Ferroelectr Freq Control. 2020;67(2):269-77.
11. Christensen-Jeffries K, Harput S, Brown J, Zhang G, Zhu J, Tang M, et al. 3D in vitro ultrasound super-resolution imaging using a clinical system. In: 2018 IEEE International Ultrasonics Symposium (IUS), pp. 1-4.
12. Ratsimandresy L, Mauchamp P, Dinet D, Felix N, Dufait R. A 3 MHz two dimensional array based on piezocomposite for medical imaging. In: 2002 IEEE Ultrasonics Symposium, 2002. Proceedings, pp. 1265-68. IEEE.
13. Stephens D, Kruse D, Qin S, Ferrara K. Design aspects of focal beams from high-intensity arrays. IEEE Trans Ultrason Ferroelectr Freq Control. 2011;58(8):1590-602.
14. Woo J, Roh Y. Ultrasonic 2D matrix array transducer for volumetric imaging in real time. In: 2012 IEEE International Ultrasonics Symposium, pp. 1568-71.
15. Lee W, Roh Y. Ultrasonic transducers for medical diagnostic imaging. Biomed Eng Lett. 2017;7(2):91-7.
16. Maffett R, Boni E, Chee AJY, Yiu BYS, Savoia AS, Ramalli A, et al. Unfocused field analysis of a density-tapered spiral array for high-volume-rate 3-D ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2022;69(10):2810-22.
17. Ramalli A, Boni E, Savoia AS, Tortoli P. Density-tapered spiral arrays for ultrasound 3-D imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2015;62(8):1580-8.
18. Nooijens S, Ramalli A, Ingram M, Fournelle M, Bertrand A, D'hooge J. Design of a sparse ellipsoidal array for volumetric ultrasound imaging of the prostate. In: 2020 IEEE International Ultrasonics Symposium (IUS), pp. 1-3.
19. Wei L, Boni E, Ramalli A, Fool F, Noothout E, van der Steen AFW, et al. Sparse 2-D PZT-on-PCB arrays with density tapering. IEEE Trans Ultrason Ferroelectr Freq Control. 2022;69(10):2798-809.
20. Rasmussen M, Jensen J. 3-D ultrasound imaging performance of a row-column addressed 2-D array transducer: a measurement study. In: 2013 IEEE International Ultrasonics Symposium (IUS), pp. 1460-63.
21. Lu J, Jiang X. Conformable row-column ultrasound arrays for abdominal imaging. In: 2019 IEEE International Ultrasonics Symposium (IUS), pp. 1753-56.
22. Nikolaev AV, de Jong L, Weijers G, Groenhuis V, Mann RM, Siepel FJ, et al. Quantitative evaluation of an automated cone-based breast ultrasound scanner for MRI-3D US image fusion. IEEE Trans Med Imaging. 2021;40(4):1229-39.
23. Vasyliev V, Vasyliev D, Naumenko K. Double optimal processing of multilateration surveillance system measurements to improve aircraft tracking. In: 2018 IEEE 5th International Conference on Methods and Systems of Navigation and Motion Control (MSNMC), pp. 166-70.
24. Rahman M, Hanuranto M, Mayasari S. Trilateration and iterative multilateration algorithm for localization schemes on wireless sensor network. In: 2017 international conference on control, electronics, renewable energy and communications (ICCREC), pp. 88-92.
25. Asmaa L, Hatim K, Abdelaaziz M. Localization algorithms research in wireless sensor network based on Multilateration and Trilateration techniques. In: 2014 Third IEEE International Colloquium in Information Science and Technology (CIST), pp. 415-9.
26. Li Y. Position and time-delay calibration of transducer elements in a sparse array for underwater ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2006;53(8):1458-67.
27. McGough RJ, Cindric D, Samulski TV. Shape calibration of a conformal ultrasound therapy array. IEEE Trans Ultrason Ferroelectr Freq Control. 2001;48(2):494-505.
28. McCall JR, Dayton PA, Pinton GF. Characterization of the ultrasound localization microscopy resolution limit in the presence of image degradation. IEEE Trans Ultrason Ferroelectr Freq Control. 2022;69(1):124-34.
29. Soulioti DE, Espindola D, Dayton PA, Pinton GF. Super-resolution imaging through the human skull. IEEE Trans Ultrason Ferroelectr Freq Control. 2020;67(1):25-36.
30. Pinton GF, Aubry JF, Tanter M. Direct phase projection and transcranial focusing of ultrasound for brain therapy. IEEE Trans Ultrason Ferroelectr Freq Control. 2012;59(6):1149-59.