Skip to main content
Intended for healthcare professionals
Restricted access
Review article
First published December 1999

Biosense Left Ventricular Electromechanical Mapping

Abstract

Biosense is a new technology for left ventricular endocardial mapping and catheter-based intramyocardial therapeutics. The system reconstructs electromechanical maps of the left ventricle without using x-ray fluoroscopy. The 3-dimensional electromechanical maps generated by the system are utilized to precisely identify viable target zones based on integration of endocardial electrical and mechanical signals for online diagnosis of myocardial viability in the catheterization laboratory. It may be used for guidance of radiofrequency ablation and may potentially be used to apply intramyocardial therapy by its integration with a laser fiber for transmyocardial laser revascularization procedures.

Get full access to this article

View all access and purchase options for this article.

References

1. Ben-Haim SA, Osadchy D, Schuster I, Gepstein L, Hayam G, Josephson ME. Nonfluoroscopic, in vivo navigation and mapping technology. Nat Med 1996;2: 1393–5.
2. Gepstein L, Hayam G, Ben-Haim SA. A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results. Circulation 1997;95: 1611–22.
3. Gepstein L, Hayam G, Shpun S, Ben-Haim SA. Hemodynamic evaluation of the heart with a non-fluoroscopic electromechanical mapping technique. Circulation 1997;96: 3672–80.
4. Kornowski R, Hong MK, Gepstein L, Goldstein S, Ellahham S, Ben-Haim SA, et al. Preliminary animal and clinical experiences using an electro-mechanical endocardial mapping procedure to distinguish infarcted from healthy myocardium. Circulation 1998;98: 1116–24.
5. Gepstein L, Goldin A, Lessick L, Hayam G, Shpun S, Schwartz Y, et al. Electromechanical characterization of chronic myocardial infarction in the canine coronary occlusion mode. Circulation 1998;98: 2055–64.
6. Fuchs S, Kornowski R, Shiran A, Pierre A, Ellahham S, Leon MB. Electromechanical characterization of myocardial hibernation in a pig model. Coronary Artery Dis 1999;3: 195–8.
7. Kornowski R, Hong MK, Leon MB. Comparison between left ventricular electro-mechanical mapping and radionuclide perfusion imaging for detection of myocardial viability. Circulation 1998;98: 1837–41.
8. Shpun S, Gepstein L, Hayam G, Ben-Haim SA. Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system. Circulation 1997;96: 2016–21.
9. Shah DC, Jais P, Haissaguerre M, Chouairi S, Takahashi A, Hocini M, et al. Three-dimensional mapping of the common atrial flutter circuit in the right atrium. Circulation 1997;96: 3904–12.
10. Kottkamp H, Hindricks G, Breithardt G, Borggrefe M. Three-dimensional electromagnetic catheter technology: Electroanatomical mapping of the right atrium and ablation of ectopic atrial tachycardia. J Cardiovasc Electrophysiol 1997;8: 1332–7.
11. Smeets JLRM, Ben-Haim SA, Rodriguez LM, Timmermans C, Wellens HJJ. New method for non-fluoroscopic endocardial mapping in humans. Circulation 1998;97: 2426–32.
12. Kornowski R, Hong MK, Haudenschild C, Kim WH, Leon MB. Feasibility and safety of percutaneous direct myocardial revascularization using Biosense system in porcine hearts. Coronary Artery Dis 1998;9: 535–40.
13. Kornowski R, Hong MK, Moses JW, Baim DS, Brennan J, Leon MB. Safety and feasibility of percutaneous direct myocardial revascularization guided by Biosense electro-mechanical left ventricular mapping. Circulation 1998;98 (Suppl I): 349.
14. Kornowski R, Hong MK, Leon MB. Current perspectives on direct myocardial revascularization. Am J Cardiol 1998;81: 44E–8E.